Seismic Effect on R.C.C.Building for Floor Wise Minimization of Column Cross Section
Keywords:
G+6 storey R.C.C. SAP 2000 Software package, constant column & reduction of columnAbstract
These project deals with the comparative study of performance of multistory R.C.C. building for floor wise reduction of column cross section and constant column cross section. For this study a G+6 storey R.C.C. building in Zone IV is selected. Horizontal seismic forces are calculated based on Equivalent static method. The R.C.C component like beam and column are designed by preparing Microsoft Excel sheet based on analysis result. The columns are designed as constant column cross section and reducing column cross section. The push over analysis is carried out on the building frame model with constant column cross section and floor wise reducing column cross section separately using SAP 2000 Software package. A comparative study is carried out for the formation of plastic hinges on column and beam, base force and displacement of the building model for constant column cross section and reducing column cross section. A comparative study of Bending moment and Shear force for the building model is also carried out constant column cross section and reducing column cross section. The quantity estimation for the beam and column is also carried out for constant column cross section and reducing column cross section building model and comparative study is carried out.
References
[1] Bahador B, Ehsan S.F.,(2012), “Comparative Study of the Static & Dynamic analysis of multistoried irregular building”, World Academy of Science, Engineering & Technolohy. Volume 71, pp 1920-1924.
[2] Beyer K., Dazio.A., Priestley M.J.N., (2008), “Elastic & Inelastic Side column models for R.C Non Rectangular Wall”, 14th World Conference on Earthquake Engineering ,October 12-17, Beijing, China.
[3] Bhatti, A,Q., Varum, H, “Application of Performance Based Nonlinear Static Pushover Analysis for Siesmic Design of RC Buildings”, 15th World Conference Earthquake Engineering ( 15 WCEE ), Lisboa 2012.
[4] Golghate K., Baradiya V., Sharma A., (2013), “Pushover Analysis of 4 Storey's Reinforced Concrete Building”. International Journal of Latest Trends in Engineering and Technology (IJLTET),Vol. 2. Issue 3 May 2013, pp 80-84.
[5] Goudar.A.D., KotiS ,. Babunarayan K.S (2012), “Sensitivity of Pushover analysis of design parameters-an analytical investigation”. International Journal of Advanced Structures and Geotechnical Engineering, ISSN 2319-5347,Volume 01, issue 02, October 2012.
[6] Hasan R, Xu, L. Grierson D.E. (2002), “Push-over analysis for performance-based seismic design”. International Journal of Computers and Structures, volume 80 (2002) pp2483–2493.
[7] Head M.C., Dario.J., Ochoa.A., (1987), “Analysis of prismatic & Linearly tapered reinforced concrete column”, Journal of Structural engineering-113,Volume -113, ASCE, pp-575-589.
[8] IS: 1893:2002 (Part1), “Criteria for Earthquake Resistant Design of Structures - general provisions for buildings”, Bureau of Indian Standards, New Delhi, 2002.
[9] IS: 875:1987 (Part1), “Code of Practice for Design Load (other than earthquake) for Buildings and Structures”, Bureau of Indian Standards, New Delhi, 2002.
[10] IS: 800:1984, “Code of Practice for General Construction in Steel”, Bureau of Indian Standards, New Delhi, 1985.
[11] IS: 456:2000, “Plain and Reinforced Concrete – Code of Practice”, Fourth revision, Bureau of Indian Standards, New Delhi.
[12] Khan R.G, Vyawahare M.R. (2013), “Pushover analysis of Tall Building with Soft Stories at Different Level”, International Journal of Applied Engineering Reaserch and Application (IJERA) Volume 3, Issue 4, July – Aug 2013 , pp176-185.
[13] Mouzzoun M., Moustachi O., Taleb A., Jalal S.,(2013),“Seismic performance assessment of reinforced concrete building using pushover analysis”, IOSR Journal of Mechanical & Civil Engineering(IOSR-JMCE),ISSN:2278-1684, Volume 5, Issue 1, pp 44-49.
[14] Pambhar.D.L., “Performance Based Pushover Analysis of R.C.C. Frames”.International Journal ofAdvanced Engineering Research and Studies E-ISSN2249–8974.IJAERS/Vol. I/ Issue III/April-June, 2012/329-333,
[15] Patil, S.S. Ghadge, S.A. Konapure, C.G. Ghadge C.A (2013), “Seismic Analysis of High-Rise Building by Response Spectrum Method”, iinternational Journal of Computational Engineering Research (Ijceronline.Com), Volume. 3, Issue. 3, pp272-279
[16] Punmia B.C, Jain A.K., Jain A.K.(2007) “Limit State Design of Reinforced Concrete as per IS 456:2000”, Laxmi publication. Pune.
[17] Setia S.,Sharma V.,(2012), “Seismic Response of RCC Building with story”, International Journal of Applied Engineering Research, ISSN 0973-4562, Volume 11, pp 1- 5.
[18] Simonini.R.C.,Rotenberg. A.,Beyer.K,(2012), “Pushover Analysis of Multistorey cantilever wall System”, 15th World Conference Earthquake Engineering ( 15 WCEE ), Lisboa 2012.
[19] SP 16: 1980, “Design Aids For Rainforced Concrete to IS: 456:1987”, Bureau of Indian Standards, New Delhi,
[20] Vijaykumar A., Venkatesh babu D.L., (2011), “A Survey of Methodologies for Seismic Evaluation of Building”, Canadian Journal on Environmental, Construction and Civil Engineering, Vol 2, No.5, June 2011, pp 50-55.
[21] Shah, V. L ., Karve S.R, “Illustrated Design of Reinforced Concrete Buildings (Design of G+3 Storied Building +Earthquake Analysis & Design) as per IS:456-2000 and IS: 1893-2000”, 5th Edition, 2005, Structures Publication. Pune.
Downloads
Published
Issue
Section
Categories
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
This work is licensed under a Creative Commons Attribution 4.0 International License.
Under this license, authors retain ownership of the copyright for their articles. By submitting to the International Journal of Advanced Research in Science, Management, and Technology (IJARSMT), authors grant the journal the right of first publication. Users are free to share, copy, and redistribute the material in any medium or format, and to adapt, remix, transform, and build upon the material for any purpose, including commercially, provided that appropriate credit is given to the original author(s) and the journal, a link to the license is provided, and any changes made are indicated.