Modified Air Cooler with Split Unit

Authors

  • Dr. Sanjay Purkar Author
  • Naman Agrawal Author
  • Naman Surana Author

Keywords:

Energy consumption, evaporative cooler, split cooling unit, humidity, comfort conditions

Abstract

Energy consumption all over the world is increasing rapidly and we need to develop ways to conserve energy for future requirement. For our comfort conditions generally we use an air conditioner, it uses a vapour compression refrigeration system. This refrigeration system consumes very large amount of power (about 1.5 KW), also the cost of this system is high. So the other option for maintaining comfort is evaporative cooler. The cost of evaporative cooler is less than that of AC; also it consumes less power than AC. The main drawback of evaporative cooler is that the air supplied by the cooler contains the large amount of humidity. Due to which when an individual sits in the air of the cooler, he/she feels stickiness on the body which is not comfortable for him/her. This project work involves the manufacturing and design of split cooling unit which will cool air but not increase its humidity. It will maintain the room at comfort conditions by recirculating the air in the room through split unit.

References

[1] T. Ravi Kiran, S.P.S. Rajput “Cooling Capacity and Energy Saving Potential of Dew Point Evaporative Cooling System for Indian Buildings” International Journal Of Renewable Energy Research , Vol.3, No.1, DEC.2012.

[2] J.K.Jain , D.A. Hindoliya “Development and Testing of Regenerative Evaporative Cooler” International Journal of Engineering Trends and Technology, Volume3 Issue 6 JUNE 2012

[3] Chuck Kutscher and Mark Eastment , “Projected Benefits of New Residential Evaporative Cooling Systems ” October 2006 • NREL/TP-550-3934 www.nrel.gov

[4] Moein farmahini farahani, Ghassem Heidarinjad, Shahram Delfani , “A Two Stage System Of Noncutrnal Radiative & Indirect Evaporative Cooling ” “ENERGY & BUILDINGS ” VOLUME 42 , JULY 2010.

[5] R.H. Turner , “Research Requirements In The Evaporative Cooling Field” , Transactions of the ASME Journal of Solar Energy Engineering, Vol. 103 (May) 89-91.. 3025

[6] Rin yun , Yunho Hwang, Reinhard Radermacher, “Comparison of Performance of a Residential Air Conditioning System Using Microchannel and Finand-Tube Heat Exchanger” International Refrigeration and Air Conditioning Conference, Paper 752. http://docs.lib.purdue.edu/iracc/752 http://ag.arizona.edu/pubs/consumereriaz9145

[7] J. Khedari R. Rawangkul, W. Chimchavee, J. Hirunlabh, A. Watanasungsuit, “Feasibility study of using agriculture waste as desiccant for air conditioning system”, The American Society Of Mechanical Engineers, Renewable Energy 28 (2003) 1617–1628.

[8] Kulkarni.R.K ,Rajput.P.S.“Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage” International Journal Of Applied Engineering research, Volume 1, No4, 2011 ISSN -0976-4259 .

[9] Mahsa Barzegar, Mohammad Layeghi, Ghanbar Ebrahimi, Yahya Hamzeh and Manouchehr Khorasani , “Experimental evaluation of the performances of cellulosic pads made out of Kraft and NSSC corrugated papers as evaporative media”, Energy Conversion and Management , vol. 54(1), pp 24-29 , 2012

[10] J.M. Wu, X. Huang, H. Zhang, “Theoretical analysis on heat and mass transfer in a direct evaporative cooler”, Applied Thermal Engineering, Volume 29, Issues 5-6, April 2009, Pages 980-984.

Downloads

Published

2021-12-30

How to Cite

Modified Air Cooler with Split Unit. (2021). International Journal of Advanced Research in Science, Management and Technology, 7(6), 1-5. https://ijarsmt.in/ijarsmt/article/view/111

Most read articles by the same author(s)

Similar Articles

31-32 of 32